产品规格原厂正品包装说明全新原装
KFU8-UFC-EX1.D频率信号转换安全栅 倍加福p+F资料图片下载
手机
产品
|
|
|
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Frequency current converter + trip value, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA, SIL/IEC 61508
|
|
|
|
|
1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Frequency current converter + trip value, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz, Output: 2 x 1 changeover contact + 4-20 mA
|
|
|
-
KFA5-DWB-Ex1.D
-
Rotation Speed Monitor
-
|
|
1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 115 V AC +/- 10 %, Output: 2 x 1 changeover contact, SIL/IEC 61508
|
|
|
-
KFA6-DWB-Ex1.D
-
Rotation Speed Monitor
-
|
|
1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 230 V AC ± 10 %, Output: 2 x 1 changeover contact, SIL/IEC 61508
|
|
|
-
KFD2-DWB-Ex1.D
-
Rotation Speed Monitor
-
|
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Start-up override, Configurable by keypad, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511, Function (P2P): Limit value, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508
|
|
|
|
|
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Selectable frequency trip values, 2 relay contact outputs, Start-up override, Selectable mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Function (P2P): Limit value+rotation direction/slip, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact, SIL/IEC 61508
|
|
|
|
|
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Rated voltage: 20 ... 30 V DC, Output: 2 x 1 changeover contact + 4-20 mA
|
|
|
|
|
2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Function (P2P): Frequency current converter with trip value and rotation direction/slip, Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz, Output: 2 x 1 changeover contact + 4-20 mA
|
|